Paliney 1100

General Alloy Overview

ASTM

N/A

Application Examples

Medical Devices

Industry Examples

Medical

Tempers

Wrought Hardened

Availible Forms

Wire, Strip

Biocompatibility and Medical Imaging Properties

Select compatibility testing for biomaterials applications has been completed and is available upon request

Temper Independent Properties

ParameterValueValue 2
Solidus, °F (°C)2885(1585)
Liquidus, °F (°C)3060(1680)
Melting Range, °F (°C)175(95)
Density, dwt/in³­ (g/cm³)132(12.5)
Specific Heat Capacity, Btu/lb·°F, (J/g·K)0.056(0.23)
Coefficient of Thermal Expansion, /°F (/K)6.2×10-6(1.2×10-5)
Thermal EMF vs Pt, μV/°F (μV/°C)6.3(11.3)
Emissivity0.303
ParameterValueValue 2
Thermal Conductivity, Btu/hr·ft·°F (W/m·k)11(19)
Temperature Coefficient of Resistance, /°F (/K)3.4×10-4(6.2×10-4)
Electrical Resistivity, Ω·cmf (µΩ·cm)230(38.3)
Electrical Conductivity, %IACS4.5
Elastic Modulus, Msi (GPa)22.8(157)
Shear Modulus, Msi (GPa)8.3(58)
Poissons Ratio0.368
Nobility, %99.9

Temper Dependent Properties

Stress Relieved - Wire - Spool 0.002 - 0.016 in. (0.05 - 0.4 mm) diameter

ParameterNominalMin
NominalMin
0.2% Offset Yield Strength, ksi (MPa)180 (1240)(N/A)
Tensile Elongation to Failure, %32.5
Vickers Microhardness, HV(N/A)
ParameterNominalMin
NominalMin
Ultimate Tensile Strength, ksi (MPa)200 (1380)180 (1240)
Knoop Microhardness, HK(N/A)

Annealed - Strip 0.002 - 0.010 in. (0.05 - 0.25 mm) diameter

ParameterNominalMin
NominalMin
0.2% Offset Yield Strength, ksi (MPa)100 (690)(N/A)
Tensile Elongation to Failure, %1710
Vickers Microhardness, HV(N/A)
ParameterNominalMin
NominalMin
Ultimate Tensile Strength, ksi (MPa)125 (860)100 (690)
Knoop Microhardness, HK280(N/A)

† - Values containing † are available upon request

Contact A Specialist

Quick Contact